A case study of the overview, process, and results of the re-tuning that was conducted in a building in Arlington, Virginia by Vornado Realty Trust in October 2012. Re-tuning provided the facilities management team with the ability to identify and understand building scheduling opportunities that drove significant, low-cost energy savings. Five measures were conducted, many of which pertained to the HVAC system.
Advanced Search
Your search resulted in 3 resourcesSort by
Retail buildings in the U.S. are second only to office buildings in total energy consumption and represent approximately 13% of energy use in commercial buildings nationwide. The Advanced Energy Retrofit Guide for Retail Buildings presents general project planning guidance as well as more detailed descriptions and financial payback metrics for the most important and relevant energy efficiency measures to provide a practical roadmap for effectively planning and implementing performance improvements in existing buildings. This guide is primarily designed for facility managers and energy managers of existing retail buildings of all sizes.
The Advanced Energy Retrofit Guide for Grocery Stores was created to help grocery store decision makers plan, design, and implement energy improvement projects in their facilities. It was designed with energy managers in mind, and presents practical guidance for kick-starting the process and maintaining momentum throughout the project life cycle.