Skip to main content
  • EERE Home
  • Programs & Offices
  • Consumer Information
Commercial Buildings Resource Database
  • EERE
  • »
  • Building Technologies Office
  • »
  • Commercial Buildings Resource Database
Share

Advanced Search

Your search resulted in 10 resources

Sort by

  • Title
  • Best Match

LEEP Case Study: University of Minnesota Parking Structure

August 2015

One of the nation’s largest schools serving over 60,000 students, the University of Minnesota (U of M) is upgrading the lighting at all 18 parking ramps and garages on its Minneapolis campus. In the Northrop Auditorium Garage, a small 24,000 square foot facility with 75 parking spots, U of M replaced low-wattage high-pressure sodium fixtures with high efficiency, lower- wattage LED fixtures with lighting controls. This Lighting Energy Efficiency in Parking (LEEP) Campaign Award winning project achieved 90% energy savings by upgrading to LEDs with lighting controls.

Download
Read more

LEEP: Hospital Parking Lighting Controls (VacaValley)

August 2015

NorthBay VacaValley Hospital completed lighting retrofits to their 150,000 square foot parking lot and its 225 parking spaces. They did so with help from The California Lighting Technology Center (CLTC) at the University of California, Davis. The project has achieved 65% savings and received a 2014 Lighting Energy Efficiency in Parking (LEEP) Campaign’s award for best use of lighting controls. In addition, the retrofits improved lighting maintenance operations and end-user satisfaction.

The lighting retrofit included replacing roughly 50 induction luminaires with new LED fixtures with embedded lighting controls.
The new LED fixtures were coupled with various kinds of lighting control systems, including a radio frequency (RF) connectivity control system that was installed in dedicated zones with passive- infrared (PIR) and long-range microwave sensors to achieve energy savings. An “ultra-smart” lighting control network was also put in place, giving facility managers the ability to adjust lighting schedules, light levels and time-out settings, monitor the system’s energy use, and receive automated alerts when luminaires require maintenance.

Download
Read more

LEEP Case Study: Big-Box Retail Parking Lot (Walmart)

August 2015

When it comes to achieving significant sustainability gains, an international retail giant has unique opportunities to cut energy use. With a total of 4,500 sites, Walmart’s commitment to efficiency in parking lighting in new construction and retrofits is paying off in major savings.

As a result of its lighting upgrades Walmart received individual Lighting Energy Efficiency in Parking (LEEP) Campaign awards for a superstore, a neighborhood market and a Sam’s Club. Across 100 stores including both new and retrofitted sites, over 40 million square feet in surfaces for parking and over 100,000 parking spaces, Walmart is saving over 15 million kWh each year as a result of lighting upgrades.

Download
Read more

LEEP Case Study: Medical Center Parking Structure (ThedaCare, Appleton)

August 2015

With 7 hospitals and 22 physician locations serving more than 9 Wisconsin counties, ThedaCare has ample room to implement and reap the benefits of building efficiency measures. At the Appleton Medical Center, ThedaCare’s Lighting Energy Efficiency in Parking (LEEP) Campaign Award winning project involved replacing inefficient medium-wattage HID lighting fixtures at a 126,000 square foot parking structure with high efficiency low-wattage LED fixtures. The resulting energy savings exceed 80 percent of the previous usage. A 100-year old company and the third largest health care employer in Wisconsin, ThedaCare has now implemented LED exterior lighting throughout Appleton Medical Center.

Download
Read more

LEEP Case Study: Retail Center Parking Lot (Kimco Realty)

August 2015

Kimco Realty Corporation’s large facility portfolio could be considered quite challenging to some organizations trying to reduce energy savings, but Kimco was able to provide upgrades to 160 sites across 25 states over 2 years. The 50-year old real estate investment trust based in New Hyde Park, New York was a 2014 Lighting Energy Efficiency in Parking (LEEP) Campaign winner for Largest Absolute Number of Facility Upgrades. Kimco has reduced their lighting energy usage primarily through the use of lighting controls for their parking lots representing approximately 51
million square feet of parking area. Kimco, which owns and operates over 800 shopping centers in North and South America, can add their LEEP accomplishments to their 2013 National Association of Real Estate Investment Trusts (NAREIT) award for leadership in sustainability and energy efficiency.

Download
Read more

LEEP Case Study: Retail Center Parking Lot (Rona Plaza)

Regency Centers is a national owner, operator, and developer of neighborhood and community shopping centers with over 300 properties throughout the United States. Regency Centers recently upgraded the parking lot lighting at Rona Plaza in Santa Ana, California. Rona Plaza is a grocery-anchored shopping center with 52,000 square-feet of gross lettable area and 250 parking spaces across 77,000 square feet of parking area. Regency Centers retrofitted the existing parking lot and exterior wall mounted fixtures, which were high-intensity discharge (HID) fixtures, with high efficiency LED fixtures coupled with a wireless dimming system. The retrofit resulted in energy savings of nearly 88% compared to pre-existing conditions and was recognized by the Lighting Energy Efficiency in Parking (LEEP) Campaign with the Highest Percentage Energy Savings in a Retrofit at a Single Parking Area award.

Download
Read more

LEEP Case Study: Casino Parking Structure

August 2015

The second largest gaming company in the world by revenue, MGM Resorts International (MGM) has recently installed energy efficient parking area lighting and controls at 65% of its U.S. facilities. With 20 U.S. facilities in NV, MI, and MS, MGM lighting projects have covered more than 8 million square feet of parking area. By replacing more than 4,400 existing metal halide and high-pressure sodium light fixtures in the parking facilities with a mixture of LED and induction fixtures, MGM saved 4.5 million kWh per year across their portfolio.

Most impressively, at the MGM Grand Detroit Casino–a 401-room hotel and gaming facility— the company achieved 4 million kWh of annual energy savings by replacing medium-wattage metal halide fixtures in a 2.6 million square foot parking structure with high efficiency, low- wattage LED fixtures.

Download
Read more

On-Site Commercial Solar PV Decision Guide

September 2014

This guide covers each major step in procuring a solar photovoltaic (PV) system:

  • Conducting technical and financial studies „
  • Financing a PV system „
  • Procurement „
  • Project execution „
  • Operations and maintenance „
  • Assessing benefits

The guide provides information on the basic steps, key considerations, and where to go for more information. It is intended to provide an overview and some level of detail, with pointers to highly detailed information and resources.

Download
Read more

Saving Energy and Water in California Schools—7x7x7: Design Energy Water

December 2016

7x7x7: Design Energy Water is an innovative program by the Division of the State Architect that encouraged California school districts to develop long-range master plans that reduce energy and water consumption on campuses and improve the quality of educational spaces. The State Architect engages seven architectural firms to develop seven conceptual case studies that reduce school energy and water consumption and result in better learning environments on seven different types of campuses (six K-12 schools and a community college). The seven campuses are representative of typical building types from different eras constructed across California’s varied climate zones. The purpose and primary goal of this program is to enable all existing K-14 facilities to be zero energy by 2030.

Download
Read more

Improving Energy Efficiency in Public Schools through Performance Contracting with Existing Budgets

June 2011

This case study, on pages 69-70 of the attached report, provides information on upgrades and activities achieving efficiencies and cost savings in public schools. The report is the McGraw-Hill Construction SmartMarket Report: "Business Case for Energy Efficient Building Retrofit and Renovation," which is listed here: https://buildingdata.energy.gov/cbrd/resource/917.

Download
Read more

Refine your search

clear all filters

resource type

  • Case Study (1) Apply Case Study filter

topic

  • Energy Efficiency (29) Apply Energy Efficiency filter
  • Lighting (28) Apply Lighting filter
  • Analysis, Benchmarking, Performance, and Monitoring (15) Apply Analysis, Benchmarking, Performance, and Monitoring filter
  • Whole Building Design (14) Apply Whole Building Design filter
  • Daylighting (13) Apply Daylighting filter
  • Building Envelope (10) Apply Building Envelope filter
  • Heating, Ventilation, and Air Conditioning (HVAC) (10) Apply Heating, Ventilation, and Air Conditioning (HVAC) filter
  • Operations and Maintenance (10) Apply Operations and Maintenance filter
  • (-) Remove Commercial Building Partnerships filter Commercial Building Partnerships
  • Social and Behavioral Impacts (8) Apply Social and Behavioral Impacts filter
  • Miscellaneous Electric Loads (7) Apply Miscellaneous Electric Loads filter
  • Renewable Energy: Solar Electric (7) Apply Renewable Energy: Solar Electric filter
  • Indoor Air Quality (3) Apply Indoor Air Quality filter
  • Sensors and Controls (3) Apply Sensors and Controls filter
  • Energy Management Systems (2) Apply Energy Management Systems filter
  • Financing (2) Apply Financing filter
  • Refrigeration (2) Apply Refrigeration filter
  • Measurement and Validation (2) Apply Measurement and Validation filter
  • Water Management (2) Apply Water Management filter
  • Program Design and Implementation (2) Apply Program Design and Implementation filter
  • Renewable Energy: General (1) Apply Renewable Energy: General filter
  • Energy Planning (1) Apply Energy Planning filter
  • Energy Modeling and Analytics (1) Apply Energy Modeling and Analytics filter
  • (-) Remove Commissioning filter Commissioning
  • Demand Response, Process Response, SmartGrid (1) Apply Demand Response, Process Response, SmartGrid filter
  • Renewable Energy: Solar Thermal (1) Apply Renewable Energy: Solar Thermal filter
  • Renewable Energy: Wind (1) Apply Renewable Energy: Wind filter

building type

  • Applies to All Building Types (4) Apply Applies to All Building Types filter
  • Mercantile (Enclosed and Strip Malls) (3) Apply Mercantile (Enclosed and Strip Malls) filter
  • K-12 Education (2) Apply K-12 Education filter
  • Mercantile (Detached/Standalone) (2) Apply Mercantile (Detached/Standalone) filter
  • Parking Garage (2) Apply Parking Garage filter
  • Health Care (Inpatient) (1) Apply Health Care (Inpatient) filter
  • Health Care (Outpatient) (1) Apply Health Care (Outpatient) filter
  • Higher Education (1) Apply Higher Education filter
  • Lodging (1) Apply Lodging filter

audience type

  • Owners (8) Apply Owners filter
  • Energy and Facility Management (6) Apply Energy and Facility Management filter
  • Academic (3) Apply Academic filter
  • Government: State (3) Apply Government: State filter
  • Government: Local (2) Apply Government: Local filter
  • Architectural and Engineering (1) Apply Architectural and Engineering filter
  • Construction and Building Contracting (1) Apply Construction and Building Contracting filter
  • Educators and Trainers (1) Apply Educators and Trainers filter
  • Financing and Investment (1) Apply Financing and Investment filter
  • Government: Federal (1) Apply Government: Federal filter
  • Applies to All Audience Types (1) Apply Applies to All Audience Types filter
  • Nonprofit (1) Apply Nonprofit filter
  • Government: Tribal (1) Apply Government: Tribal filter

primary institution

  • Other (2) Apply Other filter
  • DOE (1) Apply DOE filter

collection

  • Training: Building Retuning (24) Apply Training: Building Retuning filter
  • Commercial Building Partnerships (16) Apply Commercial Building Partnerships filter
  • (-) Remove Energy Technologies filter Energy Technologies
  • Advanced Energy Design Guides (5) Apply Advanced Energy Design Guides filter
  • Zero Energy Buildings (5) Apply Zero Energy Buildings filter
  • (-) Remove Planning and Financing K-12 Energy Efficiency filter Planning and Financing K-12 Energy Efficiency
  • Advanced Rooftop Unit Campaign (2) Apply Advanced Rooftop Unit Campaign filter
  • Resources for Small Commercial Buildings (2) Apply Resources for Small Commercial Buildings filter
  • Zero Energy for Federal Buildings: Establish Renewable Energy System Integration Process (1) Apply Zero Energy for Federal Buildings: Establish Renewable Energy System Integration Process filter
  • (-) Remove Advanced Energy Retrofit Guides filter Advanced Energy Retrofit Guides
  • Energy-Performance-Based Acquisition in Commercial Buildings (0) Apply Energy-Performance-Based Acquisition in Commercial Buildings filter
  • (-) Remove UC Davis Case Studies filter UC Davis Case Studies
  • Energy-Performance-Based Acquisition: Define a Performance-Based Acquisition Process (0) Apply Energy-Performance-Based Acquisition: Define a Performance-Based Acquisition Process filter
  • Energy-Performance-Based Acquisition: Develop Energy Performance Goals (0) Apply Energy-Performance-Based Acquisition: Develop Energy Performance Goals filter
  • Energy-Performance-Based Acquisition: Require Energy Performance (0) Apply Energy-Performance-Based Acquisition: Require Energy Performance filter
  • Energy-Performance-Based Acquisition: Manage a Performance-based Acquisition Process (0) Apply Energy-Performance-Based Acquisition: Manage a Performance-based Acquisition Process filter
  • Energy-Performance-Based Acquisition: Verify Energy Performance (0) Apply Energy-Performance-Based Acquisition: Verify Energy Performance filter
  • Energy-Performance-Based Acquisition: Goal-Based Acquisition Case Studies (0) Apply Energy-Performance-Based Acquisition: Goal-Based Acquisition Case Studies filter
  • Financing Solutions (0) Apply Financing Solutions filter
  • Policies and Programs (0) Apply Policies and Programs filter
  • Plug and Process Loads: Energy-Saving Resources (0) Apply Plug and Process Loads: Energy-Saving Resources filter
  • Energy-Performance-Based Acquisition: Annotated RFPs (0) Apply Energy-Performance-Based Acquisition: Annotated RFPs filter
  • Advanced Energy Design Guides - Models (0) Apply Advanced Energy Design Guides - Models filter
  • Zero Energy for Federal Buildings: Define Net Zero (0) Apply Zero Energy for Federal Buildings: Define Net Zero filter
  • Zero Energy for Federal Buildings: Establish Energy Efficiency System Best Practices (0) Apply Zero Energy for Federal Buildings: Establish Energy Efficiency System Best Practices filter
  • Zero Energy for Federal Buildings: Establish Zero Energy Building Operations Plan (0) Apply Zero Energy for Federal Buildings: Establish Zero Energy Building Operations Plan filter
  • Zero Energy for Federal Buildings: Verify and Report Zero Energy Building Performance (0) Apply Zero Energy for Federal Buildings: Verify and Report Zero Energy Building Performance filter
  • Refrigeration Playbook Tools (0) Apply Refrigeration Playbook Tools filter

construction type

  • Existing/Retrofit (8) Apply Existing/Retrofit filter

phase of delivery

  • Renovation and Retrofit (5) Apply Renovation and Retrofit filter
  • Operations, Maintenance, Measurement, and Verification (4) Apply Operations, Maintenance, Measurement, and Verification filter
  • Applies to All Phases of Delivery (2) Apply Applies to All Phases of Delivery filter

state

  • CA (5) Apply CA filter
  • MN (5) Apply MN filter
  • MS (4) Apply MS filter
  • NV (4) Apply NV filter
  • WI (4) Apply WI filter
  • AL (3) Apply AL filter
  • AK (3) Apply AK filter
  • AR (3) Apply AR filter
  • AZ (3) Apply AZ filter
  • CO (3) Apply CO filter
  • CT (3) Apply CT filter
  • DC (3) Apply DC filter
  • DE (3) Apply DE filter
  • FL (3) Apply FL filter
  • GA (3) Apply GA filter
  • HI (3) Apply HI filter
  • IA (3) Apply IA filter
  • ID (3) Apply ID filter
  • IL (3) Apply IL filter
  • IN (3) Apply IN filter
  • KS (3) Apply KS filter
  • KY (3) Apply KY filter
  • LA (3) Apply LA filter
  • MA (3) Apply MA filter
  • MD (3) Apply MD filter
  • ME (3) Apply ME filter
  • MI (3) Apply MI filter
  • MO (3) Apply MO filter
  • MT (3) Apply MT filter
  • NE (3) Apply NE filter
  • NH (3) Apply NH filter
  • NJ (3) Apply NJ filter
  • NM (3) Apply NM filter
  • NY (3) Apply NY filter
  • NC (3) Apply NC filter
  • ND (3) Apply ND filter
  • OK (3) Apply OK filter
  • OH (3) Apply OH filter
  • OR (3) Apply OR filter
  • PA (3) Apply PA filter
  • RI (3) Apply RI filter
  • SC (3) Apply SC filter
  • SD (3) Apply SD filter
  • TN (3) Apply TN filter
  • TX (3) Apply TX filter
  • UT (3) Apply UT filter
  • VT (3) Apply VT filter
  • VA (3) Apply VA filter
  • WA (3) Apply WA filter
  • WV (3) Apply WV filter

publication date

  • 2015 (6) Apply 2015 filter
  • 2011 (1) Apply 2011 filter
  • 2014 (1) Apply 2014 filter
  • 2016 (1) Apply 2016 filter

Contacts | Web Site Policies | U.S. Department of Energy | USA.gov