Skip to main content
  • EERE Home
  • Programs & Offices
  • Consumer Information
Commercial Buildings Resource Database
  • EERE
  • »
  • Building Technologies Office
  • »
  • Commercial Buildings Resource Database
Share

Advanced Search

Your search resulted in 4 resources

Sort by

  • Title
  • Best Match

PNC Financial Services: Maximum Efficiency Bank Branch

September 2013

PNC Financial Services partnered with DOE's Commercial Building Partnerships (CBP) Program to develop and implement solutions to retrofit its existing Singer Island, Florida, branch to reduce energy consumption by at least 30% versus ASHRAE Standard 90.1-2004. Construction was completed in January 2012.

Download
Read more

Field Evaluation of the Performance of the RTU Challenge Unit: Daikin Rebel

March 2015

In 2011, the U.S. Department of Energy’s Building Technology Office (DOE’s BTO), with help from the Better Buildings Alliance (BBA) members, developed a specification (RTU Challenge) for high performance rooftop air-conditioning units (RTUs) with capacity ranges between 10 and 20 tons (DOE 2013). Daikin’s Rebel RTU was recognized by DOE in May 2012 as first to meet the RTU Challenge specifications. This report documents the testing of a Rebel unit and a standard reference unit in the field and compares the seasonal efficiency of the two units.

The goal of the RTU Challenge demonstration was to estimate the seasonal performance of the RTU Challenge unit and the annual savings that could be achieved by installing the challenge unit instead of an alternate standard unit. The demonstration took place at two grocery stores located in New Smyrna Beach and Port Orange, Florida. The Rebel unit was installed as a replacement of an existing unit in July 2013 at the New Smyrna Beach store. The reference unit was an existing rooftop unit in the Port Orange store that is about 6 years old. The reference unit had two compressors for staged cooling and a constant-speed supply fan. Both units had the same rated cooling capacity of 7.5 tons and served each store’s office spaces with similar footprints.

A set of sensors were used to measure the dry-bulb temperature and the relative humidity for the outdoor-air, the return-air, the mixed-air, and the supply-air. RTU total power consumption was also measured using a power transducer. These sensor measurements, together with a number of control signals were monitored at 1-minute intervals from August 2013 to September 2014.

The average daily energy efficiency ratio (EER) was computed for each unit using the monitored data. The ratio of the average EER for the two units varied between 0.9 and 2.4. The Rebel unit had a higher daily EER than the reference unit for almost all days. The EER ratio increased as the daily average outdoor-air temperature decreased, as expected. This means that RTUs with variable-speed compressors and variable-speed fans, like Rebel, had better part-load efficiencies than units using constant speed supply fans and ON/OFF controls for compressors. The average of the daily EER ratio for all days was approximately 1.38, which means that on average, the daily EER of the Rebel unit was 38% higher than that of the reference unit.

In addition to daily EER, the seasonal cooling efficiency was also calculated over the entire monitoring period. Over the 12-month period, the reference unit and the Rebel unit had seasonal EERs of 8.3 and 10.9, respectively. The Rebel unit’s seasonal EER was about 31% higher than the reference unit. This result was slightly lower than the findings from our previous simulation work, which estimated that in hot and humid climates, Rebel would consume about 40% less electricity than a RTU with a constant-speed supply fan and a single-stage mechanical cooling. Possible reasons for this difference included: 1) the load that the two units in the field served were different, while the two units in the simulation served the same load; and 2) the reference unit had higher operating efficiency than the number used in the simulation runs.

The annual energy savings from the rooftop unit replacement with Rebel was about 16,000 kWh, which translated to roughly 3.8 years in simple payback.

It was a challenge to find two units running in two different spaces that had served similar cooling loads. Although two grocery stores with similar layouts were selected, the monitored data showed that they had noticeably different load profiles. Therefore, absolute energy savings between the two units could not be calculated. If the absolute savings measurement were desirable, then the existing RTU will have to be monitored for 1 year, followed by a year of monitoring of the Rebel unit after it replaces the existing RTU.

Other issues related to the installation of the Rebel unit included:
-The Rebel unit came with a different base footprint from the existing Lennox unit. Although a curb adapter was provided, it left the unit suspended over the front side of the base, and was ultimately supported by blocks.

-Although the new Rebel unit was considerably heavier than the unit it replaced, no roof reinforcement was needed.

The store that had the Rebel unit reported no comfort issues either positive or negative. The Rebel unit had a Micro Tech III controller, which was not compatible with the existing Emerson E2 BX controller, or the Emerson building automation system (BAS). Emerson had an application for the Micro Tech II controller but not for Micro Tech III. Therefore, the store had to install an output board with a set of dry contacts to control the RTU indoor fan. They also had to add an interface to monitor the indoor fan “On/Off” status and the supply/return temperatures, but they could not control any cooling/heating/speed control functions. All operations were controlled directly by the Micro Tech III controller in the unit with input from the zone temperature sensor.

The start-up and commissioning of the Rebel was challenging because the local Daikin distributor who installed the unit had very little experience in installing these new units. In addition, the controller had many features with a large instruction/operation manual, which made it difficult to properly configure. It took the distributor a couple of trips to configure the unit correctly, but after it was configured, the unit, as well as its metering and monitoring system worked as expected. Over the last 12-month period, maintenance requirements for this unit were similar to the other units.

Download
Read more

Variable Frequency Drive (VFD) Retrofit Upgrade on Rooftop Units (JC Penney case study)

August 2015

JCPenney saved over 47 million kWh and $5 million with variable frequency drive retrofits of rooftop units across 131 stores. The case study describes the decision process and results of this successful program.

Download
Read more

Design and Planning to Create More Energy-Efficient Buildings

In this video, Paul Torcellini, principal group manager for Commercial Buildings Research at the National Renewable Energy Laboratory, discusses the importance of design and planning in creating more energy-efficient buildings.

Download
Read more

Refine your search

clear all filters

resource type

  • Case Study (1) Apply Case Study filter
  • Video (1) Apply Video filter

topic

  • Commercial Building Partnerships (2) Apply Commercial Building Partnerships filter
  • Energy Efficiency (2) Apply Energy Efficiency filter
  • Heating, Ventilation, and Air Conditioning (HVAC) (2) Apply Heating, Ventilation, and Air Conditioning (HVAC) filter

building type

  • Food Sales (1) Apply Food Sales filter
  • Health Care (Inpatient) (1) Apply Health Care (Inpatient) filter
  • Health Care (Outpatient) (1) Apply Health Care (Outpatient) filter
  • Mercantile (Detached/Standalone) (1) Apply Mercantile (Detached/Standalone) filter
  • Office (1) Apply Office filter

audience type

  • Owners (9) Apply Owners filter
  • Applies to All Audience Types (6) Apply Applies to All Audience Types filter
  • Energy and Facility Management (5) Apply Energy and Facility Management filter
  • (-) Remove Architectural and Engineering filter Architectural and Engineering
  • Construction and Building Contracting (2) Apply Construction and Building Contracting filter
  • Educators and Trainers (2) Apply Educators and Trainers filter
  • Energy Modeling (2) Apply Energy Modeling filter
  • Financing and Investment (2) Apply Financing and Investment filter
  • Government: Federal (2) Apply Government: Federal filter
  • Industry and Trade Associations (2) Apply Industry and Trade Associations filter
  • Academic (1) Apply Academic filter
  • Manufacturing/Industrial (1) Apply Manufacturing/Industrial filter
  • Tenants (1) Apply Tenants filter
  • Utilities and Program Administrators (1) Apply Utilities and Program Administrators filter
  • Marketing and Outreach (1) Apply Marketing and Outreach filter

primary institution

  • PNNL (2) Apply PNNL filter
  • NREL (1) Apply NREL filter

collection

  • Commercial Building Partnerships (1) Apply Commercial Building Partnerships filter
  • Advanced Rooftop Unit Campaign (1) Apply Advanced Rooftop Unit Campaign filter
  • Advanced Energy Design Guides (0) Apply Advanced Energy Design Guides filter
  • Advanced Energy Retrofit Guides (0) Apply Advanced Energy Retrofit Guides filter
  • Energy-Performance-Based Acquisition in Commercial Buildings (0) Apply Energy-Performance-Based Acquisition in Commercial Buildings filter
  • UC Davis Case Studies (0) Apply UC Davis Case Studies filter
  • Energy-Performance-Based Acquisition: Define a Performance-Based Acquisition Process (0) Apply Energy-Performance-Based Acquisition: Define a Performance-Based Acquisition Process filter
  • Energy-Performance-Based Acquisition: Develop Energy Performance Goals (0) Apply Energy-Performance-Based Acquisition: Develop Energy Performance Goals filter
  • Energy-Performance-Based Acquisition: Require Energy Performance (0) Apply Energy-Performance-Based Acquisition: Require Energy Performance filter
  • Energy-Performance-Based Acquisition: Manage a Performance-based Acquisition Process (0) Apply Energy-Performance-Based Acquisition: Manage a Performance-based Acquisition Process filter
  • Energy-Performance-Based Acquisition: Verify Energy Performance (0) Apply Energy-Performance-Based Acquisition: Verify Energy Performance filter
  • Energy-Performance-Based Acquisition: Goal-Based Acquisition Case Studies (0) Apply Energy-Performance-Based Acquisition: Goal-Based Acquisition Case Studies filter
  • Training: Building Retuning (0) Apply Training: Building Retuning filter
  • Planning and Financing K-12 Energy Efficiency (0) Apply Planning and Financing K-12 Energy Efficiency filter
  • Financing Solutions (0) Apply Financing Solutions filter
  • Policies and Programs (0) Apply Policies and Programs filter
  • Energy Technologies (0) Apply Energy Technologies filter
  • Plug and Process Loads: Energy-Saving Resources (0) Apply Plug and Process Loads: Energy-Saving Resources filter
  • Energy-Performance-Based Acquisition: Annotated RFPs (0) Apply Energy-Performance-Based Acquisition: Annotated RFPs filter
  • Advanced Energy Design Guides - Models (0) Apply Advanced Energy Design Guides - Models filter
  • Zero Energy for Federal Buildings: Define Net Zero (0) Apply Zero Energy for Federal Buildings: Define Net Zero filter
  • Zero Energy for Federal Buildings: Establish Energy Efficiency System Best Practices (0) Apply Zero Energy for Federal Buildings: Establish Energy Efficiency System Best Practices filter
  • Zero Energy for Federal Buildings: Establish Renewable Energy System Integration Process (0) Apply Zero Energy for Federal Buildings: Establish Renewable Energy System Integration Process filter
  • Zero Energy for Federal Buildings: Establish Zero Energy Building Operations Plan (0) Apply Zero Energy for Federal Buildings: Establish Zero Energy Building Operations Plan filter
  • Zero Energy for Federal Buildings: Verify and Report Zero Energy Building Performance (0) Apply Zero Energy for Federal Buildings: Verify and Report Zero Energy Building Performance filter
  • Resources for Small Commercial Buildings (0) Apply Resources for Small Commercial Buildings filter
  • Refrigeration Playbook Tools (0) Apply Refrigeration Playbook Tools filter
  • Zero Energy Buildings (0) Apply Zero Energy Buildings filter

construction type

  • Existing/Retrofit (2) Apply Existing/Retrofit filter

phase of delivery

  • Renovation and Retrofit (1) Apply Renovation and Retrofit filter

state

  • CO (54) Apply CO filter
  • CA (4) Apply CA filter
  • (-) Remove FL filter FL
  • KY (4) Apply KY filter
  • NC (3) Apply NC filter
  • WI (3) Apply WI filter
  • AL (2) Apply AL filter
  • AK (2) Apply AK filter
  • AR (2) Apply AR filter
  • AZ (2) Apply AZ filter
  • CT (2) Apply CT filter
  • DC (2) Apply DC filter
  • DE (2) Apply DE filter
  • GA (2) Apply GA filter
  • HI (2) Apply HI filter
  • IA (2) Apply IA filter
  • ID (2) Apply ID filter
  • IL (2) Apply IL filter
  • IN (2) Apply IN filter
  • KS (2) Apply KS filter
  • LA (2) Apply LA filter
  • MA (2) Apply MA filter
  • MD (2) Apply MD filter
  • ME (2) Apply ME filter
  • MI (2) Apply MI filter
  • MN (2) Apply MN filter
  • MS (2) Apply MS filter
  • MO (2) Apply MO filter
  • MT (2) Apply MT filter
  • NE (2) Apply NE filter
  • NV (2) Apply NV filter
  • NH (2) Apply NH filter
  • NJ (2) Apply NJ filter
  • NM (2) Apply NM filter
  • NY (2) Apply NY filter
  • ND (2) Apply ND filter
  • OK (2) Apply OK filter
  • OH (2) Apply OH filter
  • OR (2) Apply OR filter
  • PA (2) Apply PA filter
  • RI (2) Apply RI filter
  • SC (2) Apply SC filter
  • SD (2) Apply SD filter
  • TN (2) Apply TN filter
  • (-) Remove TX filter TX
  • UT (2) Apply UT filter
  • VT (2) Apply VT filter
  • (-) Remove VA filter VA
  • WA (2) Apply WA filter
  • WV (2) Apply WV filter

publication date

  • 2015 (2) Apply 2015 filter
  • 2013 (1) Apply 2013 filter

Contacts | Web Site Policies | U.S. Department of Energy | USA.gov