Your search resulted in 20 resources

Sort by

  • Title
  • Best Match

LEEP: Hospital Parking Lighting Controls (VacaValley)

August 2015

NorthBay VacaValley Hospital completed lighting retrofits to their 150,000 square foot parking lot and its 225 parking spaces. They did so with help from The California Lighting Technology Center (CLTC) at the University of California, Davis. The project has achieved 65% savings and received a 2014 Lighting Energy Efficiency in Parking (LEEP) Campaign’s award for best use of lighting controls. In addition, the retrofits improved lighting maintenance operations and end-user satisfaction.

The lighting retrofit included replacing roughly 50 induction luminaires with new LED fixtures with embedded lighting controls.
The new LED fixtures were coupled with various kinds of lighting control systems, including a radio frequency (RF) connectivity control system that was installed in dedicated zones with passive- infrared (PIR) and long-range microwave sensors to achieve energy savings. An “ultra-smart” lighting control network was also put in place, giving facility managers the ability to adjust lighting schedules, light levels and time-out settings, monitor the system’s energy use, and receive automated alerts when luminaires require maintenance.

Download
Read more

LEEP Case Study: Big-Box Retail Parking Lot (Walmart)

August 2015

When it comes to achieving significant sustainability gains, an international retail giant has unique opportunities to cut energy use. With a total of 4,500 sites, Walmart’s commitment to efficiency in parking lighting in new construction and retrofits is paying off in major savings.

As a result of its lighting upgrades Walmart received individual Lighting Energy Efficiency in Parking (LEEP) Campaign awards for a superstore, a neighborhood market and a Sam’s Club. Across 100 stores including both new and retrofitted sites, over 40 million square feet in surfaces for parking and over 100,000 parking spaces, Walmart is saving over 15 million kWh each year as a result of lighting upgrades.

Download
Read more

LEEP Case Study: Retail Center Parking Lot (Kimco Realty)

August 2015

Kimco Realty Corporation’s large facility portfolio could be considered quite challenging to some organizations trying to reduce energy savings, but Kimco was able to provide upgrades to 160 sites across 25 states over 2 years. The 50-year old real estate investment trust based in New Hyde Park, New York was a 2014 Lighting Energy Efficiency in Parking (LEEP) Campaign winner for Largest Absolute Number of Facility Upgrades. Kimco has reduced their lighting energy usage primarily through the use of lighting controls for their parking lots representing approximately 51
million square feet of parking area. Kimco, which owns and operates over 800 shopping centers in North and South America, can add their LEEP accomplishments to their 2013 National Association of Real Estate Investment Trusts (NAREIT) award for leadership in sustainability and energy efficiency.

Download
Read more

LEEP Case Study: Retail Center Parking Lot (Rona Plaza)

Regency Centers is a national owner, operator, and developer of neighborhood and community shopping centers with over 300 properties throughout the United States. Regency Centers recently upgraded the parking lot lighting at Rona Plaza in Santa Ana, California. Rona Plaza is a grocery-anchored shopping center with 52,000 square-feet of gross lettable area and 250 parking spaces across 77,000 square feet of parking area. Regency Centers retrofitted the existing parking lot and exterior wall mounted fixtures, which were high-intensity discharge (HID) fixtures, with high efficiency LED fixtures coupled with a wireless dimming system. The retrofit resulted in energy savings of nearly 88% compared to pre-existing conditions and was recognized by the Lighting Energy Efficiency in Parking (LEEP) Campaign with the Highest Percentage Energy Savings in a Retrofit at a Single Parking Area award.

Download
Read more

Variable Frequency Drive (VFD) Retrofit Upgrade on Rooftop Units (JC Penney case study)

August 2015

JCPenney saved over 47 million kWh and $5 million with variable frequency drive retrofits of rooftop units across 131 stores. The case study describes the decision process and results of this successful program.

Download
Read more

Saving Energy and Water in California Schools—7x7x7: Design Energy Water

December 2016

7x7x7: Design Energy Water is an innovative program by the Division of the State Architect that encouraged California school districts to develop long-range master plans that reduce energy and water consumption on campuses and improve the quality of educational spaces. The State Architect engages seven architectural firms to develop seven conceptual case studies that reduce school energy and water consumption and result in better learning environments on seven different types of campuses (six K-12 schools and a community college). The seven campuses are representative of typical building types from different eras constructed across California’s varied climate zones. The purpose and primary goal of this program is to enable all existing K-14 facilities to be zero energy by 2030.

Download
Read more

Exterior Lighting Case Study: Networked Adaptive Exterior Lighting for Health Care Sector

May 2014

In 2014, NorthBay VacaValley Hospital became one of the first U.S. health care facilities to install an energy-efficient, ultra-smart outdoor LED lighting system. The award-winning project was so successful that the NorthBay Healthcare group is now considering expanding the VacaValley system and retrofitting the outdoor lighting at other sites.

Download
Read more

Exterior Lighting Case Study: Campus-wide Networked Adaptive LED Lighting

July 2014

UC Davis established the Smart Lighting Initiative (SLI), an effort to reduce campus-wide lighting electricity consumption at least 60% below 2007 levels. The first phase of this program included a large-scale deployment of over 1,500 network-controlled LED streetlights, area lights, post-tops, and wall packs. The “ultra-smart” lighting installation has reduced annual energy use by an estimated 1,231,758 kWh, saving $120,909 annually in energy and maintenance costs.

Download
Read more

Garden Grove [California] School District ZE retrofits

January 2018

Six-page case study of the Santiago High School Science Building and the Ralston Intermediate Building K: Multipurpose Room and Kitchen retrofits. These projects are classified by NBI as “ZE emerging”—they have a stated ZE goal, but their performance has not yet been verified with 12 months of energy use and generation data.

Download
Read more

Los Osos [California] Middle School ZE retrofit

January 2018

Four-page case study of the Los Osos Middle School zero energy retrofit, which is classified by NBI as “ZE emerging”—it has a stated
ZE goal, but its performance has not yet been verified with 12 months of energy use and generation data.

Download
Read more

Pages

  • 1
  • 2
  • next ›
  • last »

Refine your search

clear all filters

resource type

  • Case Study (8) Apply Case Study filter
  • Fact Sheet (2) Apply Fact Sheet filter
  • Report (1) Apply Report filter

topic

  • Lighting (15) Apply Lighting filter
  • Energy Efficiency (12) Apply Energy Efficiency filter
  • Analysis, Benchmarking, Performance, and Monitoring (7) Apply Analysis, Benchmarking, Performance, and Monitoring filter
  • Commercial Building Partnerships (4) Apply Commercial Building Partnerships filter
  • Sensors and Controls (4) Apply Sensors and Controls filter
  • Heating, Ventilation, and Air Conditioning (HVAC) (2) Apply Heating, Ventilation, and Air Conditioning (HVAC) filter
  • Operations and Maintenance (2) Apply Operations and Maintenance filter
  • Daylighting (1) Apply Daylighting filter
  • Energy Management Systems (1) Apply Energy Management Systems filter
  • Building Envelope (1) Apply Building Envelope filter
  • Financing (1) Apply Financing filter
  • Indoor Air Quality (1) Apply Indoor Air Quality filter
  • Miscellaneous Electric Loads (1) Apply Miscellaneous Electric Loads filter
  • Renewable Energy: General (1) Apply Renewable Energy: General filter
  • Social and Behavioral Impacts (1) Apply Social and Behavioral Impacts filter
  • Energy Modeling and Analytics (1) Apply Energy Modeling and Analytics filter
  • Commissioning (1) Apply Commissioning filter
  • Measurement and Validation (1) Apply Measurement and Validation filter
  • Demand Response, Process Response, SmartGrid (1) Apply Demand Response, Process Response, SmartGrid filter
  • Water Management (1) Apply Water Management filter
  • Program Design and Implementation (1) Apply Program Design and Implementation filter
  • Renewable Energy: Solar Electric (1) Apply Renewable Energy: Solar Electric filter

building type

  • Applies to All Building Types (5) Apply Applies to All Building Types filter
  • Higher Education (2) Apply Higher Education filter
  • Mercantile (Enclosed and Strip Malls) (2) Apply Mercantile (Enclosed and Strip Malls) filter
  • Mercantile (Detached/Standalone) (2) Apply Mercantile (Detached/Standalone) filter
  • Office (2) Apply Office filter
  • Food Service (1) Apply Food Service filter
  • Health Care (Inpatient) (1) Apply Health Care (Inpatient) filter
  • K-12 Education (1) Apply K-12 Education filter
  • Manufacturing/Industrial Facility (1) Apply Manufacturing/Industrial Facility filter
  • Parking Garage (1) Apply Parking Garage filter
  • Warehouse and Storage (1) Apply Warehouse and Storage filter

audience type

  • Owners (14) Apply Owners filter
  • Energy and Facility Management (13) Apply Energy and Facility Management filter
  • Applies to All Audience Types (5) Apply Applies to All Audience Types filter
  • Academic (3) Apply Academic filter
  • Energy Modeling (3) Apply Energy Modeling filter
  • Architectural and Engineering (2) Apply Architectural and Engineering filter
  • Government: State (2) Apply Government: State filter
  • Government: Local (2) Apply Government: Local filter
  • Construction and Building Contracting (1) Apply Construction and Building Contracting filter
  • Educators and Trainers (1) Apply Educators and Trainers filter
  • Financing and Investment (1) Apply Financing and Investment filter
  • Government: Federal (1) Apply Government: Federal filter
  • Government: Tribal (1) Apply Government: Tribal filter

primary institution

  • Other (9) Apply Other filter
  • DOE (2) Apply DOE filter
  • NREL (2) Apply NREL filter

collection

  • UC Davis Case Studies (8) Apply UC Davis Case Studies filter
  • Commercial Building Partnerships (4) Apply Commercial Building Partnerships filter
  • Energy Technologies (4) Apply Energy Technologies filter
  • Zero Energy Buildings (4) Apply Zero Energy Buildings filter
  • Planning and Financing K-12 Energy Efficiency (1) Apply Planning and Financing K-12 Energy Efficiency filter
  • Advanced Rooftop Unit Campaign (1) Apply Advanced Rooftop Unit Campaign filter
  • Resources for Small Commercial Buildings (1) Apply Resources for Small Commercial Buildings filter
  • Advanced Energy Design Guides (0) Apply Advanced Energy Design Guides filter
  • Advanced Energy Retrofit Guides (0) Apply Advanced Energy Retrofit Guides filter
  • Energy-Performance-Based Acquisition in Commercial Buildings (0) Apply Energy-Performance-Based Acquisition in Commercial Buildings filter
  • Energy-Performance-Based Acquisition: Define a Performance-Based Acquisition Process (0) Apply Energy-Performance-Based Acquisition: Define a Performance-Based Acquisition Process filter
  • Energy-Performance-Based Acquisition: Develop Energy Performance Goals (0) Apply Energy-Performance-Based Acquisition: Develop Energy Performance Goals filter
  • Energy-Performance-Based Acquisition: Require Energy Performance (0) Apply Energy-Performance-Based Acquisition: Require Energy Performance filter
  • Energy-Performance-Based Acquisition: Manage a Performance-based Acquisition Process (0) Apply Energy-Performance-Based Acquisition: Manage a Performance-based Acquisition Process filter
  • Energy-Performance-Based Acquisition: Verify Energy Performance (0) Apply Energy-Performance-Based Acquisition: Verify Energy Performance filter
  • Energy-Performance-Based Acquisition: Goal-Based Acquisition Case Studies (0) Apply Energy-Performance-Based Acquisition: Goal-Based Acquisition Case Studies filter
  • Training: Building Retuning (0) Apply Training: Building Retuning filter
  • Financing Solutions (0) Apply Financing Solutions filter
  • Policies and Programs (0) Apply Policies and Programs filter
  • Plug and Process Loads: Energy-Saving Resources (0) Apply Plug and Process Loads: Energy-Saving Resources filter
  • Energy-Performance-Based Acquisition: Annotated RFPs (0) Apply Energy-Performance-Based Acquisition: Annotated RFPs filter
  • Advanced Energy Design Guides - Models (0) Apply Advanced Energy Design Guides - Models filter
  • Zero Energy for Federal Buildings: Define Net Zero (0) Apply Zero Energy for Federal Buildings: Define Net Zero filter
  • Zero Energy for Federal Buildings: Establish Energy Efficiency System Best Practices (0) Apply Zero Energy for Federal Buildings: Establish Energy Efficiency System Best Practices filter
  • Zero Energy for Federal Buildings: Establish Renewable Energy System Integration Process (0) Apply Zero Energy for Federal Buildings: Establish Renewable Energy System Integration Process filter
  • Zero Energy for Federal Buildings: Establish Zero Energy Building Operations Plan (0) Apply Zero Energy for Federal Buildings: Establish Zero Energy Building Operations Plan filter
  • Zero Energy for Federal Buildings: Verify and Report Zero Energy Building Performance (0) Apply Zero Energy for Federal Buildings: Verify and Report Zero Energy Building Performance filter
  • Refrigeration Playbook Tools (0) Apply Refrigeration Playbook Tools filter

construction type

  • (-) Remove Existing/Retrofit filter Existing/Retrofit
  • New Construction (8) Apply New Construction filter

phase of delivery

  • Renovation and Retrofit (7) Apply Renovation and Retrofit filter
  • Operations, Maintenance, Measurement, and Verification (2) Apply Operations, Maintenance, Measurement, and Verification filter
  • Applies to All Phases of Delivery (1) Apply Applies to All Phases of Delivery filter

state

  • (-) Remove CA filter CA
  • CO (7) Apply CO filter
  • DC (7) Apply DC filter
  • CT (6) Apply CT filter
  • HI (6) Apply HI filter
  • MA (6) Apply MA filter
  • MD (6) Apply MD filter
  • MN (6) Apply MN filter
  • FL (5) Apply FL filter
  • MS (5) Apply MS filter
  • NV (5) Apply NV filter
  • PA (5) Apply PA filter
  • RI (5) Apply RI filter
  • SC (5) Apply SC filter
  • VA (5) Apply VA filter
  • WI (5) Apply WI filter
  • AL (4) Apply AL filter
  • AK (4) Apply AK filter
  • AR (4) Apply AR filter
  • AZ (4) Apply AZ filter
  • DE (4) Apply DE filter
  • GA (4) Apply GA filter
  • (-) Remove IA filter IA
  • ID (4) Apply ID filter
  • IL (4) Apply IL filter
  • IN (4) Apply IN filter
  • KS (4) Apply KS filter
  • (-) Remove KY filter KY
  • LA (4) Apply LA filter
  • ME (4) Apply ME filter
  • MI (4) Apply MI filter
  • MO (4) Apply MO filter
  • MT (4) Apply MT filter
  • NE (4) Apply NE filter
  • NH (4) Apply NH filter
  • NJ (4) Apply NJ filter
  • NM (4) Apply NM filter
  • NY (4) Apply NY filter
  • NC (4) Apply NC filter
  • ND (4) Apply ND filter
  • OK (4) Apply OK filter
  • OH (4) Apply OH filter
  • OR (4) Apply OR filter
  • SD (4) Apply SD filter
  • TN (4) Apply TN filter
  • TX (4) Apply TX filter
  • UT (4) Apply UT filter
  • VT (4) Apply VT filter
  • WA (4) Apply WA filter
  • WV (4) Apply WV filter

publication date

  • 2012 (5) Apply 2012 filter
  • 2015 (4) Apply 2015 filter
  • 2013 (3) Apply 2013 filter
  • 2017 (3) Apply 2017 filter
  • 2018 (3) Apply 2018 filter
  • 2014 (2) Apply 2014 filter
  • 2011 (1) Apply 2011 filter
  • 2016 (1) Apply 2016 filter

Contacts | Web Site Policies | U.S. Department of Energy | USA.gov